Indubitably, the flow rate of gas mass is measured by a gas mass flow meter, depending on the heat transfer of a heated surface. The two temperature sensors are the main elements of a mass flow meter with an electric heater between them.

Gas Mass Flow Meter

Most of the time in past, that mass flow was calculated from the densitometer and the volumetric flow meter outputs. However, the density was calculated via the pressure transmitters and the process temperatures output or measured directly.

Since the relationship between the process temperature or pressure and density is not always exactly known for every sensor, these flow measurements are not very precise.

How does a mass flow meter work?

The mass flow meter works either by maintaining a probe at a consistent temperature, measuring the energy needed to do so, or presenting a known heat amount into the flowing stream and measuring a correlated temperature change.

If the flow meters function at a consistent temperature-difference mode, they provide a high rangeability. However, the detection ability of minor temperature differences will be limited if the heat input is consistent, and both the rangeability and the precision will drop off. Moreover, the measurement errors are normally 1-2% full-scale at normal flow.

A manometer device is a most commonly used for gas pressure measuring device.

Common mass flow meter applications

These flow meters are mostly used to examine or manage mass-relevant processes like chemical reactions based on the relative masses of unreacted items such as custody transfer options, billing, recipe formulations and material balance determinations.

The accuracy and the reliability of mass flow measurement are crucial since these are the essential flow measurements in-plant processing. The measurement is not affected by the changes in temperature and the pressure to detect the mass flow of compressible gasses and vapours.

Gas Mass Flow Meter

Meticulously, when used at consistent-temperature-difference mode, these flowmeters will give a high rangeability. In addition, the measurement errors are normally in the 1-2% full-scale range at the normal flows.

These sensors are available in high-temperature, and high-pressure designs, delivered in specialised materials including glass, Monel and PFA. However, flow-through designs are used to measure the small flows of pure substances, whereas the probe-type and bypass designs can detect big flows in flare stacks, dryers, and ducts.

The most common gas-flow applications for gas mass flow meter are semiconductor process gas measurement, process gas measurement, gas chromatography, air sampling in nuclear power plants, filter, and leak testing, including combustion air measurement in big boilers.

For more information Click here!